CDWCT - EXTREME PRESSURE LUBE 3

Product Identification

Product ID:EXTREME PRESSURE LUBE 3
MSDS Date:01/01/1992
FSC:9150
NIIN:00N001097
MSDS Number: CDWCT

Responsible Party
CHICAGO MFG AND DISTRIBUTION CO
6592 LINCOLN ST
GAGETOWN, MI 48735
US

Emergency Phone: 517-665-2531

Info Phone: 800-537-2956

Cage: GO978

Contractor
CHICAGO MFG AND DISTRIBUTION CO
GAGETOWN, MI 48735 US

Telephone: 800-537-2956

Cage: GO978

Ingredients

ALL SUCH CONTRS SHOULD BE DISP OF IN ENVIRON SAFE

RTECS: 9999999ZZ


TANKS REFER TO OSHA REGS, ANSI Z 49.1, & OTHER GOVT

RTECS: 9999999ZZ


REPAIRING, WELDING AND/OR OTHER CONTEMPLATED

RTECS: 9999999ZZ


AIR. EXPLO-PROOF EQUIP MAY BE REQUIRED. CONTACT NEHC

RTECS: 9999999ZZ


BEFORE REUSE. REMOVE CONTAM SHOES & THORO

RTECS: 9999999ZZ


IGNITED, USE WATER SPRAY TO DISPERSE VAPS & TO

RTECS: 9999999ZZ


SPRAY MAY BE USED TO FLUSH SPILLS AWAY FROM EXPOS.

RTECS: 9999999ZZ


GASES, VAPOR, FUMES OR DECOMPOSITION PRODUCTS.

RTECS: 9999999ZZ


SKIN, REGARDLESS OF AMT INJECTED/APPEAR OF

RTECS: 9999999ZZ


LOSS OF THE AFFECTED PART OF THE BODY.

RTECS: 9999999ZZ


SEWERS & WATERCOURSES BY DIKING/IMPOUNDING.

RTECS: 9999999ZZ


WATERCOURSES/EXTENSIVE LAND AREAS. MIN SKIN CONT.

RTECS: 9999999ZZ


TRANSPORT. FOR FURTHER INFO RELATIVE TO SPILLS

RTECS: 9999999ZZ


DEPARTMENT OF TRANSPORTATION EMER RESPONSE

RTECS: 9999999ZZ


PROD W/HIGH PRESS GREASE GUN BE ESP CAREFUL TO

RTECS: 9999999ZZ


PART. EMPTY CONTRS CONTAIN RESIDUE (LIQ & VAP)

RTECS: 9999999ZZ


BRAZE, SOLDER, DRILL, GRIND/EXPOSE SUCH CONTRS TO

RTECS: 9999999ZZ


EXPLODE & CAUSE INJURY/DEATH. DO NOT ATTEMPT TO

RTECS: 9999999ZZ


"EMPTY" DRUMS SHOULD BE COMPLETELY DRAINED, PROPERLY

RTECS: 9999999ZZ


PETROLEUM HYDROCARBON PENNZOIL D23-66 OIL

RTECS: 9999999ZZ

Fraction By Weight: 58.99%

OSHA PEL 5 MG/M3 (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


PARAFFIN; (PETROLEUM WAX; WITCO CHEMICAL MULTI WAX 445)

CAS: 8002-74-2

RTECS: RV0350000

Fraction By Weight: 14.30%

OSHA PEL 2 MG/M3 (FUME)

ACGIH TLV: 2 MG/M3 (FUME)


GLYCEROL ESTER OF HYDROGENATED ROSIN; (ROSIN ESTER;

CAS: 65997-13-9

Fraction By Weight: 5.00%

OSHA PEL N/K

ACGIH TLV: N/K


POLYOXYETHYLENE DINONYLPHENYL ETHER PHOSPHATE

CAS: 39464-64-7

Fraction By Weight: 21.69%

OSHA PEL N/K

ACGIH TLV: N/K


FRAGRANCE COMPOUND; NEUTROLINE #4609

Fraction By Weight: 0.02%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HLTH STUDIES HAVE SHOWN THAT MANY
PETRO HYDROCARBONS & SYNTHETIC LUBRICANT BLENDS POSE POTENTIAL
HUMAN HLTH RISKS WHICH MAY DIFFER FROM ONE PERS TO ANOTHER. FOR
THIS REASON, EXPOS TO SUCH MATLS IN FOR M OF LIQS, VAPS,
MISTS/FUMES SHOULD BE MIN. ACUTE:EYE:MAY CAUSE BURNING, IRRIT &
MILD CONJ (1-3 DAYS). (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SKIN:MAY RSLT IN IRRIT/DERM ON
PRLNG/RPTD EXPOS. INJECTION BENEATH SKIN/ANY OTHER PART OF BODY BY
HIGH PRESS GREASE GUN CAUSES SERIOUS DELAYED SOFT TISS DMG & SHOULD
BE TREATED IMMED AS SURGI CAL EMER. INHAL:IN MIST MAY CAUSE LOC
IRRIT, DIZZ, DROW, PNEUM. INGEST:UNKNOWN. CONT NEHC FOR MORE
SPECIFIC INFO .
Medical Cond Aggravated by Exposure:SKIN IRRITATION OR DERMATITIS MAY
BE AGGRAVATED ESPECIALLY IN INDIVIDUALS WHO MAY HAVE DEVELOPED A
HIGH DEGREE OF HYPERSENSITIVITY AS A RESULT OF PROLONGED OR
REPEATED EXPOSURE.

First Aid

First Aid:EYE: FLUSH W/CLEAR WATER FOR AT LEAST 15 MIN/LONGER UNTIL
IRRIT SUBSIDES. CALL MD IMMED. SKIN: REMOVE CONTAM CLTHG. WASH SKIN
W/SOAP & WATER. CONTAM CLTHG MUST BE WASHED BEFORE REUSE. INHAL:
REMOVE TO FRESH AIR IMMED. IF BRTHG STOPPED, START RESUSCITATION
PROC INCL ARTF RESP & ADMIN OXYGEN AS NEC. CALL MD IMMED. INGEST:
DO NOT INDUCE VOMIT. CALL MD IMMED. INJECTION: IF INJECTED BENEATH
(ING 9)

Fire Fighting

Flash Point Method:COC
Flash Point:446F,230C
Lower Limits:0.9%
Upper Limits:7.0%
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEMICAL, CARBON
DIOXIDE AND VAPORIZING LIQUID (HALON).
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
CONSULT LOC FIRE FIGHTING AUTH FOR APPROP FIRE PROT & FIRE RESPONSE
STRATEGY. USE WATER SPRAY TO COOL (SUP DAT)
Unusual Fire/Explosion Hazard:DENSE SMOME & FUMES, CARBON MONOXIDE,
CARBON DIOXIDE, ALDEHYDES, NITROGEN OXIDES, PHOSPHINE AND/OR OTHER
DECOMPOSITION PRODUCTS OF ORGANIC PHOSPHORUS COMPOUNDS.

Accidental Release

Spill Release Procedures:COLLECT LGE SPILLS W/SHOVEL, DRY SAND/OIL
ABSORB MATLS. CLEAN SPILL AREA W/AQUEOUS DETERGENT SOLNS. PROVIDE
ADEQ VENT DURING CLEAN-UP TO PVNT EXCEEDING REC EXPOS LIM FOR OIL,
MIST/FUME/BUILD-UP OF EXP LO CONCS OF VAP IN AIR. KEEP PROD OUT OF
(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN SEALED CONTRS AWAY FROM HEAT,
OPEN FLAMES & OXIDIZING MATLS. KEEP APPROP FIRE EXTING AGENTS
READILY AVAIL & TRAIN PERS IN THEIR PROPER USE.
Other Precautions:KEEP DRY SAND/OIL ABSORB MATL READILY AVAIL & TRAIN
PERS IN THEIR PROPER USE IN CASE OF SPILLAGE. SEE NFPA 30 & OSHA
1910.106-FLAM & COMBUST LIQS. DO NOT TRANFER TO UNMARKED CONTRS.
FOLLOW DEPARTMENT OF TRANSPORTATION REGS DURING (ING 13)

Exposure Controls

Respiratory Protection:LOW CONCS: PARTIAL/FULL-FACE RESP W/NIOSH APPRVD
ORG VAP CANISTER. HIGH CONCS: NIOSH APPRVD FULL-FACE PIECE SUPP AIR
BRTHG APPARATUS. EITHER SCBA/AIR-LINE BRTHG APPARATUS. DO NOT USE
COMPRESSED OXYGEN SYS IN HYDROCARBON ATMOSPHERES.
Ventilation:LOC EXHST VENT SUFFICIENT TO PVNT EXCEEDING REC EXPOS LIM
FOR ALL MIST/FUME/BUILD-UP OF EXPLO CONCS OF VAP IN (ING 23)
Protective Gloves:CHEMICAL RESISTANT SYNTHETIC RUBBER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
CHEM RESIST APRON/OTHER IMPERVIOUS CLTHG TO PVNT CONTAM REG CLTHG.
Work Hygienic Practices:MIN BRTHG OF VAP, MIST, SPRAY/FUMES. AVOID
PRLNG/RPTD CONT W/SKIN. REMOVE CONTAM CLTHG; LAUNDER/DRY-CLEAN (ING
24)
Supplemental Safety and Health
FIRE FIGHT PROC: FIRE-EXPOSED CONTRA & STOR TANKS & TO PROT PERS.
WATER, EXCEPT IN FORM OF FINE SPRAY/FOG, MAY BE INEFFECTIVE FOR
FIRE FIGHTING & SHOULD NOT BE USED EXCEPT TO COOL CONTR & STOR
TANKS E XPOSED TO HEAT/FLAME. IMPROPER APPLICATION OF LIQ WATER TO
BURNING LIQ CAN CAUSE BOILOVER. IF LEAK/SPILL HAS NOT (ING 6)

Chemical Properties

Boiling Pt:B.P. Text:>246F,>119C
Melt/Freeze Pt:M.P/F.P Text:130F,54C
Vapor Pres:0.3
Vapor Density:>20
Spec Gravity:0.9510 (H*2O=1)
Evaporation Rate & Reference:ESSENTIALLY NON-VOLATILE
Solubility in Water:NIL
Appearance and Odor:GREASE-LIKE SEMI-SOLID DARKER THAN 8.0 ON ASTM
D1500 SCALE, SLIGHT PLEASANT ODO

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, OXYGEN, LIQUID OXYGEN, LIQUID CHLORINE, SODIUM
HYPOCHLORITE, CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF PHOSPHORUS, CARBON AND
NITROGEN, ALDEHYDES, PHOSPHINE AND OTHER TOXIC OXIDES AND FUMES.

Disposal

Waste Disposal Methods:WASTE MATL SHOULD BE DISP OF BY INCIN IN
SUITABLE COMBUST SYS CAPABLE OF HNDLG GREASE-LIKE PRODS. USED PROD
MAY BE SUITABLE FOR RECLAMATION/RE-REFINING IF NOT CONTAM. DISP
MUST COMPLY W/ALL APPLIC GOV T REGS. DISP OF I/A/W STATE, LOC & FED
REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.